Field Equipment
BATSCANNER
BATSCANNERSpecifications:
These are the specifications of the BATSCANNER
| Field of application | Mobile bat detecton |
| Audio | |
| Acoustic signal processing | Heterodyne conversion |
| Type of microphone | Electret-condenser |
| Number of microphones | 1 |
| Sensitivity range | 15–120kHz |
| Live monitoring | Heterodyne |
| Trigger function | yes |
| Audio out | 3.5mm plug / speaker |
| Manual peak frequency selection | yes |
| Operation | |
| Display | 7-Segment LED |
| Interface | Push-buttons |
| Casing | |
| Size (WxLxD) | 62 x 120 x 27 mm |
| Weight | 145g |
| Protection class | Not waterproof |
| Power | |
| Power supply | 3x 1,5 V batteries type AAA |
| Operating time | 20-25h |
BATSCANNER STAND
BATSCANNER STANDSpecifications:
These are the specifications of the BATSCANNER
| Field of application | Static bat detecton |
| Audio | |
| Acoustic signal processing | Heterodyne conversion |
| Type of microphone | Electret-condenser |
| Number of microphones | 1 |
| Sensitivity range | 15–120kHz |
| Live monitoring | Heterodyne |
| Trigger function | yes |
| Audio out | Speaker” |
| Manual peak frequency selection | no |
| Operation | |
| Display | LED |
| Interface | Push-button |
| Casing | |
| Size (WxLxD) | 130 x 130 x 78 mm |
| Weight | 350g |
| Protection class | IP66 |
| Power | |
| Power supply | 12 V DC to 18 V DC, min. 5W |
BATSCANNER STEREO
BATSCANNER STEREOSpecifications:
These are the specifications of the BATSCANNER STEREO
| Field of application | Mobile bat detecton |
| Audio | |
| Acoustic signal processing | Stereo heterodyne conversion |
| Type of microphone | Electret-condenser |
| Number of microphones | 2 |
| Sensitivity range | 15–120kHz |
| Live monitoring | Heterodyne |
| Trigger function | yes |
| Audio out | 3.5mm plug / speaker |
| Manual peak frequency selection | yes |
| Operation | |
| Display | 7-Segment LED |
| Interface | Push-buttons |
| Casing | |
| Size (WxLxD) | 62 x 120 x 27 mm |
| Weight | 145g |
| Protection class | Not waterproof |
| Power | |
| Power supply | 3x 1,5 V batteries type AAA |
| Operating time | 20-25h |
Carbon Fiber Rescue Pole
Carbon Fiber Rescue PoleCarbon Fiber Rescue Pole
Carbon Fiber Rescue PoleCarbon fiber rescue pole is a specialized tool used in rescue operations to reach and extract individuals from hazardous situations.
- Material: Carbon Fiber
- Surface: 3K Twill
- Sections: 4 ~ 9
- Clamps: Heavy-duty Quick-release Style
- Length: 6m, 9m, 13m, 17m and Customized Lengths
- Accessories: Clamp Flotation, Flotation Collar, Body Hook, Simple Hook, 3-Braces Hook
CompactPRO Thermal Imaging Camera
CompactPRO Thermal Imaging CameraCompactPRO Thermal Imaging Camera
CompactPRO Thermal Imaging CameraCompactPRO Thermal Imaging Camera
Powerful thermal imaging cameras designed for your smartphone.
Made for iPhone® and Android™ top models, Seek Compact transforms your smartphone or tablet into a professional thermal imaging tool. By utilizing the power and convenience of your smartphone, our cameras make it easy to take thermal photos and video, share findings, and send for documentation. Simply connect and detect energy loss caused by air leaks, missing or damaged insulation, inefficient HVAC systems, electrical faults, and much more. On top of all this, Seek Compact cameras are engineered to run on low power from your smartphone and do not require batteries or charging.
High Resolution Thermal Imaging
CompactPRO is our most advanced smartphone camera yet with unprecedented thermal resolution.
- 320 x 240 Thermal Sensor
- 32° Field of View
- < 9 Hz Frame Rate
- 1,800 ft. Detection Distance
- Focusable Lens
- -40F° to 626°F Detection
- Waterproof Case Included
- Photos & Videos
- Spot Temperature
- High-Low Temperature
- Threshold Mode
- 9 Color Palettes
- Auto & Span/Level Control
- Adjustable Emissivity
D1000X Ultrasound Detector
D1000X Ultrasound DetectorD1000X Ultrasound Detector
D1000X Ultrasound DetectorD1000X Ultrasound Detector
The D1000X is a professional ultrasound detector, based on the latest technology. The detector has heterodyne, frequency division and time expansion systems and also a built-in 16-bit recording system using a Compact Flash card as storage medium. It is equipped with our well-known, high-quality capacitance microphone which has been further improved to give lower noise, wider dynamic range and lower distortion.
The D1000X has a built-in “recorder”, relieving the user from the hassle of operating a separate recording device or laptop with connecting cables. It can be configured to work in a variety of operating modes, but thanks to the use of “Profiles”, switching between different modes is made instantly. Each profile contains all the selectable settings such as sampling rate, triggering mode, time expansion factor and LED intensity and can be prepared in advance and saved in the detector.
At any time, either the direct ultrasonic signal, the heterodyne signal or the frequency division signal can be recorded onto the CF-card. Spoken comments can be recorded by speaking into the microphone while recording in the direct mode, or in a special comment recording mode (at a lower sampling rate). The recording time is limited only by the available space on the CF-card. Upon completion of a recording in the direct mode, the signal will be automatically replayed in time expanded form, if this function is enabled. Time expansion factors from 1 (original speed) to 30 can be chosen. The recordings can be made by manually starting and stopping the recording or through level-activated (and optional frequency selective) triggering. In the latter case, the detector can be set up for unattended capture of calls. Pre- and post-triggering modes with a variety of different settings can be used.
The wav sound files on the CF-card are stamped with date and time and can be read directly on a PC, using a standard CF-card reader. The D1000X also has a serial GPS input, making it possible to save GPS position data in the files.
D230 Ultrasound Detector
D230 Ultrasound DetectorD230 Ultrasound Detector
A combined heterodyne and frequency division detector with backlit, large digit, accurate digital display, showing the tuned frequency in the heterodyne mode. The frequency and volume controls are on the side of the case, making it easy to adjust. Using stereo headphones, the heterodyne signal is heard on the left channel and the frequency division signal on the right channel. When the built-in speaker is used, a switch is used to select the heterodyne or frequency division signal.
| Weight | 160 g |
| Dimensions | 119 × 60 × 25 mm |
| Type | Heterodyne and frequency division |
| Microphone | Electret |
| Frequency range | 10-120 kHz (min.) |
| Display accuracy | ± 0.15 kHz |
| Bandwidth | 8 kHz (+/- 4 kHz), -6 dB |
| Battery | 1 x IEC 6LF22 (9V) |
| Quiescent current | 23 mA typ. including LCD backlight |
| Outputs | 2 x 3.5 mm jacks for headphones and recorder |
D240x Ultrasound Detector
D240x Ultrasound DetectorD240x Ultrasound Detector
D240x Ultrasound DetectorD240x Ultrasound Detector
Very popular heterodyne and time expansion detector with backlit, large digit, accurate digital display, showing the tuned frequency in the heterodyne mode. The frequency and volume controls are on the side of the case, making it easy to adjust. Using stereo headphones, the heterodyne signal is heard on the left channel and the time expansion signal on the right channel. When the built-in speaker is used, a switch is used to select the heterodyne or time expansion signal.
A digital recorder can be connected to the D240X to record the time expanded calls for analysis on a PC. If the recorder has a “voice activated” recording mode, a fully automatic bat recording system is obtained, which can be left in the field for unattended recording of bat calls.
| Weight | 170 g |
| Dimensions | 119 × 60 × 25 mm |
| Type | Heterodyne and time expansion (x10 or x20 – selectable via switch) |
| Microphone | Advanced electret |
| Frequency range | 10-120 kHz (min.) |
| Display accuracy | ± 0.15 kHz |
| Bandwidth | 8 kHz (+/- 4 kHz), -6 dB |
| Battery | 1 x IEC 6LF22 (9V) |
| Quiescent current | 30 mA typ. (replay) including LCD backlight |
| Comment switch | Yes |
| Memory size | 1M x 8 |
| Sampling frequency | 307 kHz |
| Resolution | 8 bits |
| Storage time | 3.4, 1.7 or 0.1 sec. (selectable via switch) |
| Trigger modes | Manual, level – broadband, level – narrowband |
| Pretrigger | 50% of the selected storage time |
| Outputs | 2 x 3.5 mm jacks for headphones and tape recorder |
| Miscellaneous | Overload indicator, adjustable input gain, replay of signal in memory through heterodyne system |
D500X Ultrasound Detector/Recorder Mk I
D500X Ultrasound Detector/Recorder Mk ID500X Ultrasound Detector/Recorder Mk I
D500X Ultrasound Detector/Recorder Mk ID500X Ultrasound Detector/Recorder Mk I
The D500X is an ultrasound recording unit intended for long-term, unattended recording of bat calls. In contrast to time expansion bat detectors, the D500X records full-spectrum ultrasound in real time with virtually no gaps between recordings. The recorder is equipped with four slots for CF cards, which typically makes it possible to leave the unit in the field for more than a month. The triggering system allows the device to automatically start recording as a sound is detected.
| Weight | 1200 g |
| Dimensions | 165 × 170 × 53 mm |
| Class | Direct, high-speed recording |
| Microphone | Advanced electret, jack for external microphone |
| Frequency range | 15 kHz – 190 kHz (500 kHz sampling rate, high-pass filter enabled) 5 kHz – 190 kHz (500 kHz sampling rate, high-pass filter disabled) |
| Connections | External microphone, external trigger, external DC supply |
| Timer | Four on/off periods per day |
| Bandwidth | 8 kHz (+/- 4 kHz), -6 dB |
| Batteries | 4 x AA size, Alkaline or NiMH recommended |
| External DC supply | 5.5-8 V, typically ca. 200 mA (average, when recording), depends on CF card type and number of CF cards |
| Recording | ADC Resolution: 16 bits Anti-aliasing filter: Yes, 8th order, 190 kHz cut-off frequency Sampling rates: 44.1, 300, 500 kHz (optimized for 500 kHz) Recording length: 0.3, 0.5, 1, 2, 3, 5, 10, 20 sec or manual recording Recording medium: CF card, 4 slots |
D500X Ultrasound Detector/Recorder Mk II
D500X Ultrasound Detector/Recorder Mk IID500X Ultrasound Detector/Recorder Mk II
D500X Ultrasound Detector/Recorder Mk IID500X Ultrasound Detector/Recorder Mk II
The D500X Mk II is as easy to use and provides the same features as the classic D500X, with the following exceptions:
- It does not include an internal microphone. Instead it ships with an external microphone which is either directly connected to the microphone jack or through an extension cable. The microphone jack is an XLR type so no adapter cable is required.
- It is powered by 4 C type batteries which last roughly three times longer than the AA batteries used in the classic D500X.
- The jack for external power is a standard 2.5 mm DC power jack for easy connection.
- Description
- Additional information
The D500X is an ultrasound recording unit intended for long-term, unattended recording of bat calls. In contrast to time expansion bat detectors, the D500X records full-spectrum ultrasound in real time with virtually no gaps between recordings. The recorder is equipped with four slots for CF cards, which typically makes it possible to leave the unit in the field for more than a month. The triggering system allows the device to automatically start recording as a sound is detected.
| Weight | 1300 g |
| Dimensions | 165 × 170 × 53 mm |
| Class | Direct, high-speed recording |
| Microphone | Advanced electret, jack for external microphone |
| Frequency range | 15 kHz – 190 kHz (500 kHz sampling rate, high-pass filter enabled) 5 kHz – 190 kHz (500 kHz sampling rate, high-pass filter disabled) |
| Connections | External microphone, external trigger, external DC supply |
| Timer | Four on/off periods per day |
| Batteries | 4 x AA size, Alkaline or NiMH recommended |
| External DC supply | 5.5-8 V, typically ca. 200 mA (average, when recording), depends on CF card type and number of CF cards |
| Recording | ADC Resolution: 16 bits Anti-aliasing filter: Yes, 8th order, 190 kHz cut-off frequency Sampling rates: 44.1, 300, 500 kHz (optimized for 500 kHz) Recording length: 0.3, 0.5, 1, 2, 3, 5, 10, 20 sec or manual recording Recording medium: CF card, 4 slots |
Digital Hygro-Thermometer
Digital Hygro-ThermometerDigital Hygro-Thermometer
Digital Hygro-ThermometerDigital Hygro-Thermometer
This Hygro-Thermometer meets the GLOBE Protocols for air temperature, relative humidity, soil temperature and maximum-minimum and current temperatures. Features include large, bold numbers, a dual display for temperature and humidity, max/min temperature and humidity memory, and a freeze alert. Mounts easily by key hole, Velcro®, magnet or the flip-out desk stand.
DP Coon Trap
DP Coon TrapCoil Spring Traps are foot-hold restraining devices used to catch and hold wild animals. This style of trap has been in use since the early part of the 20th century and is widely accepted as a cost effective and efficient tool for managing wildlife populations. Coil Spring Traps are manufactured of steel components and powered by a set of compact coil springs. Models range from the small #1 CS with a 4″ jaw spread for Mink to the larger #4 CS 4X with a 6.5″ jaw spread for Coyote. Duke also offers three models of humane rubber padded jaw traps for Fox and Coyote.
Estwing® Pointed-Tip Rock Picks
Estwing® Pointed-Tip Rock PicksEstwing® Pointed-Tip Rock Picks
Estwing® Pointed-Tip Rock PicksEstwing Pointed-Tip Rock Pick, 7”, 22 oz. Head; 13”L, Blue Grip
Forged, one-piece solid steel. Nylon-vinyl grip.
Picks may chip when struck against rocks or other hardened surfaces or tools. Always wear safety goggles. Bystanders should also wear safety goggles
Extech® EasyView Light Meter
Extech® EasyView Light MeterExtech® EasyView Light Meter
Extech® EasyView Light MeterExtech EasyView Light Meter
This compact meter features a large, easy-to-read display with bar graph. Measures foot candles up to 40,000 in four ranges and up to 400,000 lux in five ranges. The meter utilizes a precision silicon photodiode sensor and features a 5’ coiled cable for easy storage. Other features include min/max function, cosine and color corrected measurements, peak hold, data hold, auto power-off, and indicators for low battery and overrange. Built-in stand, remote sensor with protective cover, protective holster, and 6 AAA batteries included.
Fish Ray Handheld Sonar Depth Sounder
Fish Ray Handheld Sonar Depth SounderFish Ray Handheld Sonar Depth Sounder
Fish Ray Handheld Sonar Depth SounderFish Ray Handheld Sonar Depth Sounder Model FR300
Operating Depth: 2’ to 399’.
Simply place the nose end of the Fish Ray in the water and pull the trigger to quickly obtain water depth measurements. Readings instantly appear on the digital LCD display in feet. Once you determine a stable bottom depth, you can then slowly sweep the Fish Ray through the water to scan for sudden depth changes that indicate the presence of fish or contour variations. The rugged, high-impact housing is waterproof and floats.