Outdoor Gears
Anabat Scout Active Bat Detector
Anabat Scout Active Bat DetectorAnabat Scout Active Bat Detector
Anabat Scout Active Bat DetectorAnabat Scout Active Bat Detector
The Anabat Scout is an affordable, full spectrum bat detector designed specifically for active bat monitoring.
Titley Scientific have developed a bat detector tailored to your active survey needs. The Anabat Scout is an easy-to-use unit that can play heterodyne, auto-heterodyne and frequency division audio through earphones or the built-in speaker. But it’s not limited to live listening, you can record full spectrum and zero crossing files to an SD card, with every file geo-tagged. You can even record voice notes to the SD Card.
The Scout’s features don’t end with acoustics, it also has an in/out bat counter which time stamps and geotags every count. It is robust and ergonomically designed, and comes with a protective carry pouch with belt loop and lanyard. For those on the go, use the Scout in transect mode with the built-in GPS so you can save your track. When you get back to the office, you can analyse and view your files on a map with your track using the free Anabat Insight software.
Titley Scientific knows you like to work in the dark, the small black OLED display isn’t distracting, only giving you the crucial information, and can be operated in bright or dim modes. The glow-in-the-dark buttons means that you can find and operate your detector even on the darkest night without your headtorch!
Features:
- Easy to use and robust
- Record in either full spectrum or zero crossing
- Listen in heterodyne, auto-heterodyne & frequency division audio
- In & out bat counter with automatic time stamping and geotagging
- Built-in GPS for transect mode and geotagging
- Glow in the dark buttons, easy to find at night
- Record voice notes
- Includes a protective carry pouch and lanyard
- Comes with free version of Anabat Insight software
Anabat Walkabout Active Bat Detector
Anabat Walkabout Active Bat DetectorAnabat Walkabout Active Bat Detector
Anabat Walkabout Active Bat DetectorThe Anabat Walkabout is a professional active bat detector
with everything you need in one device.
A 5″ colour touchscreen displays full spectrum and zero crossing calls in real time, enabling you to monitor and label your files in the field.
The Walkabout uses a profile system to give you fast access to customizable settings for different uses. You can lock your settings and export your profiles to other Walkabout detectors. With the touch of a button you can change the Walkabout from a heterodyne ‘listening’ detector, into a detector optimized to collect full spectrum, annotated reference calls.
In addition to the real-time sonogram display, you can switch to basic mode which shows minimal information for those that find a live display distracting.
Managing your recordings is simple with everything saved to a memory card, and a built-in file system for viewing, play-back, and species labelling.
The detector includes an omnidirectional microphone with a directional cone attachment to reduce ambient noise. Recording high quality (500 ksps) files up to 200 kHz. Save written or voice memos, along with temperature, humidity and ambient light measurements.
The hand strap, lanyard and ergonomic design makes active detection for long periods comfortable. A built-in GPS and mapping system allows you to tag your calls and log your track as you go.
This custom-designed detector goes beyond the toy microphones of the competition and provides active performance second to none.
Features
- Full colour 5” touchscreen display
- 500 ksps 16 bit sample rate
- FG Knowles microphone
- Multiple audio modes (including time expansion and heterodyne)
- Temperature, humidity and ambient light sensors
- Built-in GPS and Wi-Fi enabled
- Android operating system (no phone or tablet required)
- Free version of Anabat Insight analysis software
Includes
Wall Charger, USB Cable, earphones, hand strap, lanyard, directional cone attachment and microfiber cleaning cloth.
Animal and Reptile Handling Gloves
Animal and Reptile Handling GlovesAnimal and Reptile Handling Gloves
Animal and Reptile Handling GlovesAnimal and Reptile Handling Gloves
Offer complete dexterity while providing maximum puncture resistance.
Manufactured from top grain cowhide with a double layer of ballistic Kevlar Felt on the fingers, hand and cuff for maximum protection against the intrusion of sharp objects. Seams are in-stitched with 100% Kevlar thread. 24” Long
Animal Handling Gloves Gauntlet Leather Kevlar for Cats, Dogs, Reptile, Birds, Snakes (Color May Vary)
Animal Handling Gloves Gauntlet Leather Kevlar for Cats, Dogs, Reptile, Birds, Snakes (Color May Vary)Animal Handling Gloves Gauntlet Leather Kevlar for Cats, Dogs, Reptile, Birds, Snakes (Color May Vary)
Animal Handling Gloves Gauntlet Leather Kevlar for Cats, Dogs, Reptile, Birds, Snakes (Color May Vary)Animal Handling Gloves Gauntlet Leather Kevlar for Cats, Dogs, Reptile, Birds, Snakes (Color May Vary)
SUPERIOR SECURITY FOR FOREARMS – The 14 inches extra long glove with 7.5 inches long sleeve protect your Fingers and Forearm from Animal bite, Cat scratch, Parrot grabbing, Eagle grabbing, Snake bite etc.
THICK AND DURABLE – Leather Animal Handling Gloves are made from carefully-selected thick and soft split natural leather which is Puncture Resistant, Cut Resistant, Bite Resistant, Heat Resistant, and Fire Resistant. This pair of heavy duty gloves will last for a long time.
USED By: Veterinarians, Animal Control Staff, Groomers, Kennel Workers, Zoo Workers, Pet Shop Employees, Breeders/Handlers, Pet owners, Bird handlers, Reptile handlers
BatCounter Large
BatCounter LargeTechnical specifications
- Detection Technique: 32 modulated infrared barrier beams detecting direction
- Minimum detection size: ≥ 25 mm
- Frame Size/Weight: 80 x 39 x 7 cm, 2800 g (Standard model)
- Active detection area: 76 x 35 cm (Standard model)
- Mounting: 4x M6 eye bolts are supplied to suspend the BatCounter
- 8x M6 female threads are foreseen for custom mounting
- Power supply: 8x AA batteries or external 12V (10..16V)
- Power Consumption: ≤ 40 mA under normal use. (Approx. 3 days on fresh .Varta “High Energy” AA batteries)
- Memory: SD Card, FAT16 or FAT32, up to 32 GB
- Configuration: Configuration via file on SD card
- Field software updates: Via SD Card update files.
- File formats: CSV or TXT
- User interface: User interface shows system status. The user interface is protected by a removable aluminium cover
- Mobile phone functionalities: Warnings: SMS / email
- Daily totals: SMS / email
- Daily reports: email
- An IP67 mobile phone antenna with SMA connector, SIM card and network coverage are required to use this feature
- Clock: Internal real-time clock
- Clock Accuracy: }3 min/year (0°C .. +50°C)}6 min/year (-10°C .. +60°C)
- Clock backup time: More than one year after a full operational period of 24 hours or more (internal clock battery recharge time)
- Camera trigger: For Nikon and Canon wired with 2.5mm jack and infrared is advised for reliability and speed.
BatCounter Powerkit
BatCounter PowerkitIn principle, the eight AA batteries in the BatCounter are only used to test the device or to count over very short periods of time (e.g. a few nights). If you wish to use the BatCounter over longer periods, it is recommended that you connect to a 12-volt battery or the 1110/ 220-volt electricity network. The kit contains the following parts: – 110/ 220V BatCounter External Power Adapter – BatCounter External Power Cable.
BatCounter Small
BatCounter SmallTechnical specifications
- Detection Technique: 32 modulated infrared barrier beams detecting direction
- Minimum detection size: ≥ 25 mm
- Frame Size/Weight: 40 x 39 x 7 cm, 2200 g (Tree model)
- Active detection area: 36 x 35 cm (Tree model)
- Mounting: 4x M6 eye bolts are supplied to suspend the BatCounter
- 8x M6 female threads are foreseen for custom mounting
- Power supply: 8x AA batteries or external 12V (10..16V)
- Power Consumption: ≤ 40 mA under normal use. (Approx. 3 days on fresh .Varta “High Energy” AA batteries)
- Memory: SD Card, FAT16 or FAT32, up to 32 GB
- Configuration: Configuration via file on SD card
- Field software updates: Via SD Card update files.
- File formats: CSV or TXT
- User interface: User interface shows system status. The user interface is protected by a removable aluminium cover
- Mobile phone functionalities: Warnings: SMS / email
- Daily totals: SMS / email
- Daily reports: email
- An IP67 mobile phone antenna with SMA connector, SIM card and network coverage are required to use this feature
- Clock: Internal real-time clock
- Clock Accuracy: }3 min/year (0°C .. +50°C)}6 min/year (-10°C .. +60°C)
- Clock backup time: More than one year after a full operational period of 24 hours or more (internal clock battery recharge time)
- Camera trigger: For Nikon and Canon wired with 2.5mm jack and infrared is advised for reliability and speed.
BatLure
BatLureSpecifications
-
Every BatLure package includes:
-
1 BatLure
-
1 carrying case with sufficient room for accessories
-
1 external power cable for a 12V power input
-
1 SD-card with several pre-recorded sounds*
*Recordings have been provided by Michel Barataud
BatLure External Speaker
BatLure External SpeakerBatLure External Speaker
The newest addition to the Batlure family
- The speaker connector fits to BatLures with serial number BL1307001 and above
- Easy plug and play connection
- Splash-water proof making it suitable for outside use.
- Weight: 300 g
- Cable length: 3 meter
- Dimensions: 65 x 65 x 53 mm
- Power: ~6W
BatLure Powerkit
BatLure PowerkitThe adapter makes it possible to connect the BatLure to the electricity network (110/ 220 volts). The constant power supply enables the BatLure to transmit for extended periods. In situations in which the BatLure is used to support the mitigation to new accommodation, this is a valuable addition. Consider, for example, mitigating measures where bats need to migrate from a building that’s about to be demolished. Even when the BatLure is being used to give indoor bat detector training, it’s useful when it can be connected to the electricity network. The kit contains the following parts: – 110/ 220V BatLure External Power Adapter – BatLure External Power Cable
D1000X Ultrasound Detector
D1000X Ultrasound DetectorD1000X Ultrasound Detector
D1000X Ultrasound DetectorD1000X Ultrasound Detector
The D1000X is a professional ultrasound detector, based on the latest technology. The detector has heterodyne, frequency division and time expansion systems and also a built-in 16-bit recording system using a Compact Flash card as storage medium. It is equipped with our well-known, high-quality capacitance microphone which has been further improved to give lower noise, wider dynamic range and lower distortion.
The D1000X has a built-in “recorder”, relieving the user from the hassle of operating a separate recording device or laptop with connecting cables. It can be configured to work in a variety of operating modes, but thanks to the use of “Profiles”, switching between different modes is made instantly. Each profile contains all the selectable settings such as sampling rate, triggering mode, time expansion factor and LED intensity and can be prepared in advance and saved in the detector.
At any time, either the direct ultrasonic signal, the heterodyne signal or the frequency division signal can be recorded onto the CF-card. Spoken comments can be recorded by speaking into the microphone while recording in the direct mode, or in a special comment recording mode (at a lower sampling rate). The recording time is limited only by the available space on the CF-card. Upon completion of a recording in the direct mode, the signal will be automatically replayed in time expanded form, if this function is enabled. Time expansion factors from 1 (original speed) to 30 can be chosen. The recordings can be made by manually starting and stopping the recording or through level-activated (and optional frequency selective) triggering. In the latter case, the detector can be set up for unattended capture of calls. Pre- and post-triggering modes with a variety of different settings can be used.
The wav sound files on the CF-card are stamped with date and time and can be read directly on a PC, using a standard CF-card reader. The D1000X also has a serial GPS input, making it possible to save GPS position data in the files.
D230 Ultrasound Detector
D230 Ultrasound DetectorD230 Ultrasound Detector
A combined heterodyne and frequency division detector with backlit, large digit, accurate digital display, showing the tuned frequency in the heterodyne mode. The frequency and volume controls are on the side of the case, making it easy to adjust. Using stereo headphones, the heterodyne signal is heard on the left channel and the frequency division signal on the right channel. When the built-in speaker is used, a switch is used to select the heterodyne or frequency division signal.
Weight | 160 g |
Dimensions | 119 × 60 × 25 mm |
Type | Heterodyne and frequency division |
Microphone | Electret |
Frequency range | 10-120 kHz (min.) |
Display accuracy | ± 0.15 kHz |
Bandwidth | 8 kHz (+/- 4 kHz), -6 dB |
Battery | 1 x IEC 6LF22 (9V) |
Quiescent current | 23 mA typ. including LCD backlight |
Outputs | 2 x 3.5 mm jacks for headphones and recorder |
D240x Ultrasound Detector
D240x Ultrasound DetectorD240x Ultrasound Detector
D240x Ultrasound DetectorD240x Ultrasound Detector
Very popular heterodyne and time expansion detector with backlit, large digit, accurate digital display, showing the tuned frequency in the heterodyne mode. The frequency and volume controls are on the side of the case, making it easy to adjust. Using stereo headphones, the heterodyne signal is heard on the left channel and the time expansion signal on the right channel. When the built-in speaker is used, a switch is used to select the heterodyne or time expansion signal.
A digital recorder can be connected to the D240X to record the time expanded calls for analysis on a PC. If the recorder has a “voice activated” recording mode, a fully automatic bat recording system is obtained, which can be left in the field for unattended recording of bat calls.
Weight | 170 g |
Dimensions | 119 × 60 × 25 mm |
Type | Heterodyne and time expansion (x10 or x20 – selectable via switch) |
Microphone | Advanced electret |
Frequency range | 10-120 kHz (min.) |
Display accuracy | ± 0.15 kHz |
Bandwidth | 8 kHz (+/- 4 kHz), -6 dB |
Battery | 1 x IEC 6LF22 (9V) |
Quiescent current | 30 mA typ. (replay) including LCD backlight |
Comment switch | Yes |
Memory size | 1M x 8 |
Sampling frequency | 307 kHz |
Resolution | 8 bits |
Storage time | 3.4, 1.7 or 0.1 sec. (selectable via switch) |
Trigger modes | Manual, level – broadband, level – narrowband |
Pretrigger | 50% of the selected storage time |
Outputs | 2 x 3.5 mm jacks for headphones and tape recorder |
Miscellaneous | Overload indicator, adjustable input gain, replay of signal in memory through heterodyne system |
D500X Ultrasound Detector/Recorder Mk I
D500X Ultrasound Detector/Recorder Mk ID500X Ultrasound Detector/Recorder Mk I
D500X Ultrasound Detector/Recorder Mk ID500X Ultrasound Detector/Recorder Mk I
The D500X is an ultrasound recording unit intended for long-term, unattended recording of bat calls. In contrast to time expansion bat detectors, the D500X records full-spectrum ultrasound in real time with virtually no gaps between recordings. The recorder is equipped with four slots for CF cards, which typically makes it possible to leave the unit in the field for more than a month. The triggering system allows the device to automatically start recording as a sound is detected.
Weight | 1200 g |
Dimensions | 165 × 170 × 53 mm |
Class | Direct, high-speed recording |
Microphone | Advanced electret, jack for external microphone |
Frequency range | 15 kHz – 190 kHz (500 kHz sampling rate, high-pass filter enabled) 5 kHz – 190 kHz (500 kHz sampling rate, high-pass filter disabled) |
Connections | External microphone, external trigger, external DC supply |
Timer | Four on/off periods per day |
Bandwidth | 8 kHz (+/- 4 kHz), -6 dB |
Batteries | 4 x AA size, Alkaline or NiMH recommended |
External DC supply | 5.5-8 V, typically ca. 200 mA (average, when recording), depends on CF card type and number of CF cards |
Recording | ADC Resolution: 16 bits Anti-aliasing filter: Yes, 8th order, 190 kHz cut-off frequency Sampling rates: 44.1, 300, 500 kHz (optimized for 500 kHz) Recording length: 0.3, 0.5, 1, 2, 3, 5, 10, 20 sec or manual recording Recording medium: CF card, 4 slots |
D500X Ultrasound Detector/Recorder Mk II
D500X Ultrasound Detector/Recorder Mk IID500X Ultrasound Detector/Recorder Mk II
D500X Ultrasound Detector/Recorder Mk IID500X Ultrasound Detector/Recorder Mk II
The D500X Mk II is as easy to use and provides the same features as the classic D500X, with the following exceptions:
- It does not include an internal microphone. Instead it ships with an external microphone which is either directly connected to the microphone jack or through an extension cable. The microphone jack is an XLR type so no adapter cable is required.
- It is powered by 4 C type batteries which last roughly three times longer than the AA batteries used in the classic D500X.
- The jack for external power is a standard 2.5 mm DC power jack for easy connection.
- Description
- Additional information
The D500X is an ultrasound recording unit intended for long-term, unattended recording of bat calls. In contrast to time expansion bat detectors, the D500X records full-spectrum ultrasound in real time with virtually no gaps between recordings. The recorder is equipped with four slots for CF cards, which typically makes it possible to leave the unit in the field for more than a month. The triggering system allows the device to automatically start recording as a sound is detected.
Weight | 1300 g |
Dimensions | 165 × 170 × 53 mm |
Class | Direct, high-speed recording |
Microphone | Advanced electret, jack for external microphone |
Frequency range | 15 kHz – 190 kHz (500 kHz sampling rate, high-pass filter enabled) 5 kHz – 190 kHz (500 kHz sampling rate, high-pass filter disabled) |
Connections | External microphone, external trigger, external DC supply |
Timer | Four on/off periods per day |
Batteries | 4 x AA size, Alkaline or NiMH recommended |
External DC supply | 5.5-8 V, typically ca. 200 mA (average, when recording), depends on CF card type and number of CF cards |
Recording | ADC Resolution: 16 bits Anti-aliasing filter: Yes, 8th order, 190 kHz cut-off frequency Sampling rates: 44.1, 300, 500 kHz (optimized for 500 kHz) Recording length: 0.3, 0.5, 1, 2, 3, 5, 10, 20 sec or manual recording Recording medium: CF card, 4 slots |