Bat Detector
Anabat Walkabout Active Bat Detector
Anabat Walkabout Active Bat DetectorAnabat Walkabout Active Bat Detector
Anabat Walkabout Active Bat DetectorThe Anabat Walkabout is a professional active bat detector
with everything you need in one device.
A 5″ colour touchscreen displays full spectrum and zero crossing calls in real time, enabling you to monitor and label your files in the field.
The Walkabout uses a profile system to give you fast access to customizable settings for different uses. You can lock your settings and export your profiles to other Walkabout detectors. With the touch of a button you can change the Walkabout from a heterodyne ‘listening’ detector, into a detector optimized to collect full spectrum, annotated reference calls.
In addition to the real-time sonogram display, you can switch to basic mode which shows minimal information for those that find a live display distracting.
Managing your recordings is simple with everything saved to a memory card, and a built-in file system for viewing, play-back, and species labelling.
The detector includes an omnidirectional microphone with a directional cone attachment to reduce ambient noise. Recording high quality (500 ksps) files up to 200 kHz. Save written or voice memos, along with temperature, humidity and ambient light measurements.
The hand strap, lanyard and ergonomic design makes active detection for long periods comfortable. A built-in GPS and mapping system allows you to tag your calls and log your track as you go.
This custom-designed detector goes beyond the toy microphones of the competition and provides active performance second to none.
Features
- Full colour 5” touchscreen display
- 500 ksps 16 bit sample rate
- FG Knowles microphone
- Multiple audio modes (including time expansion and heterodyne)
- Temperature, humidity and ambient light sensors
- Built-in GPS and Wi-Fi enabled
- Android operating system (no phone or tablet required)
- Free version of Anabat Insight analysis software
Includes
Wall Charger, USB Cable, earphones, hand strap, lanyard, directional cone attachment and microfiber cleaning cloth.
BAT DETECTOR CARRYING CASE
BAT DETECTOR CARRYING CASEA close fitting hard shell case suitable for Bat4 and Bat5.
BATLOGGER C
BATLOGGER CSpecifications:
These are just some of the technical specifications, for more information check the manual of the BATLOGGER C.
Field of application | Passive long-term monitoring |
Audio/Recording | |
Acoustic signal processing | Real time 16bit-full spectrum |
Type of microphone | FG black/green |
Number of microphones | 1 |
Sensitivity range | 10–150kHz |
Live monitoring | Heterodyne (automatic or manual) |
Manual peak frequency selection | yes |
Trigger function | yes, adjustable |
Scheduler | yes, adjustable, with sunset/sunrise times |
Audio out | 3.5mm plug |
Automatic microphone test | optional |
Storage | SD card, max 256GB |
Operation | |
Display | LCD with backlight |
Interface | Push-buttons |
Connectivity | SMS/Email notification (status/alerts) |
Cellular radio | 2G Quad-band GSM/GPRS (850 / 900 / 1800 / 1900 MHz) |
GPS | yes |
Sensors | Temperature |
Casing | |
Size (WxLxD) | 224 x 191 x 99 mm |
Weight | 1.55kg |
Protection class | IP67 |
Power | |
Power supply | 7.2 battery pack / mains power / solar panel |
Operating time | 50h per battery pack |
BATLOGGER M
BATLOGGER MSpecifications:
These are just some of the technical specifications, for more information check the manual of the BATLOGGER M.
Field of application | Active (mobile) monitoring |
Audio/Recording | |
Acoustic signal processing | Real time 16bit-full spectrum |
Type of microphone | FG black/green |
Number of microphones | 1 |
Sensitivity range | 10–150kHz |
Live monitoring | Heterodyne (automatic or manual) |
Manual peak frequency selection | yes |
Trigger function | yes, adjustable |
Scheduler | yes, adjustable, with sunset/sunrise times |
Audio out | 3.5mm plug / speaker |
Storage | SD card, max 256GB |
Operation | |
Display | LCD with backlight |
Interface | Push-buttons |
GPS | yes |
Sensors | Temperature |
Casing | |
Size (WxLxD) | 80 x 155 x 38 mm |
Weight | 350g |
Protection class | IP30 |
Power | |
Power supply | internal rechargeble battery |
Operating time | 18h per battery charge |
BATLOGGER RS X8
BATLOGGER RS X8Specifications:
These are just some of the technical specifications, for more information check the manual of the BATLOGGER RS X.
Field of application | bat research |
Audio/Recording | |
Acoustic signal processing | up to 1 MHz, 24-bit |
Type of microphone | BATLOGGER X Microphone |
Number of microphones | 8 |
Sensitivity range | 10–150kHz |
Trigger function | yes |
Scheduler | yes, adjustable, with sunset/sunrise times |
Automatic microphone test | yes |
Storage | Internal hard disk (for approx. 100GByte user data) |
Datatransfer | BATLOGGER Connect cloud synchronisation SD/SDHC/SDXC cards (SD 2.0), max. 128 GB, FAT32 formatted external hard disk via USB port, FAT32 or ext4 formatted USB stick formatted via USB port, FAT32 or ext4 |
Operation | |
Display | Status LEDs |
Interface | Webinterface |
Connectivity | BATLOGGER Connect Remote monitoring, configuration and data synchronisation |
Cellular radio | 4G LTE (Europe/APAC or N. America) |
Sensors | |
Temperature | yes |
Humidity | 0 .. 100% RH relative humidity ± 3% RH (max), 0–80% RH |
Air pressure | 500 hPa .. 1100 hPa Measuring range absolute air pressure Calibratable to relative air pressure of the location Accuracy relative air pressure ±0.5 hPa (-10 .. 50°C) |
Casing | |
Size (WxLxD) | 374 x 262 x 308 mm |
Weight | 17.6 kg (with Lead Crystal® Battery) 4.4 kg without battery |
Protection class | IP64 (except microphone, ext. power supply) |
Power | |
Power supply | 24V DC 24W / solar panel 12V 50W |
Battery | Lead Crystal® Battery (considered normal goods for airfreight and shipping) |
Operating time | ∞ |
BATLOGGER WE X
BATLOGGER WE XSpecifications:
These are just some of the technical specifications, for more information check the manual of the BATLOGGER WE X.
Field of application | Wind turbine monitoring |
Audio/Recording | |
Acoustic signal processing | Real time 16bit-full spectrum |
Type of microphone | BATLOGGER X Microphone |
Number of microphones | 1, 2 or 4 |
Sensitivity range | 10–150kHz |
Trigger function | yes |
Scheduler | yes, adjustable, with sunset/sunrise times |
Automatic microphone test | yes |
Storage | Internal hard disk (for approx. 100GByte user data) |
Datatransfer | BATLOGGER Connect cloud synchronisation SD/SDHC/SDXC cards (SD 2.0), max. 128 GB, FAT32 formatted external hard disk via USB port, FAT32 or ext4 formatted USB stick formatted via USB port, FAT32 or ext4 |
Operation | |
Display | Status LEDs |
Interface | Webinterface |
Connectivity | BATLOGGER Connect Remote monitoring, configuration and data synchronisation |
Cellular radio | 4G LTE (Europe/APAC or N. America) |
Sensors | |
Temperature | yes |
Humidity | 0 .. 100% RH relative humidity ± 3% RH (max), 0–80% RH |
Air pressure | 500 hPa .. 1100 hPa Measuring range absolute air pressure Calibratable to relative air pressure of the location Accuracy relative air pressure ±0.5 hPa (-10 .. 50°C) |
Casing | |
Size (WxLxD) | 250 x 200 x 100 mm |
Weight | 2.04kg |
Protection class | IP30 |
Operating conditions | 0… 45°C 10..90 %RH (non-condensing) Charging mode: 0..+40°C |
Power | |
Power supply | 100-240 VAC, (12 VDC 30W) |
Operating time | ∞ |
BATSCANNER
BATSCANNERSpecifications:
These are the specifications of the BATSCANNER
Field of application | Mobile bat detecton |
Audio | |
Acoustic signal processing | Heterodyne conversion |
Type of microphone | Electret-condenser |
Number of microphones | 1 |
Sensitivity range | 15–120kHz |
Live monitoring | Heterodyne |
Trigger function | yes |
Audio out | 3.5mm plug / speaker |
Manual peak frequency selection | yes |
Operation | |
Display | 7-Segment LED |
Interface | Push-buttons |
Casing | |
Size (WxLxD) | 62 x 120 x 27 mm |
Weight | 145g |
Protection class | Not waterproof |
Power | |
Power supply | 3x 1,5 V batteries type AAA |
Operating time | 20-25h |
BATSCANNER STAND
BATSCANNER STANDSpecifications:
These are the specifications of the BATSCANNER
Field of application | Static bat detecton |
Audio | |
Acoustic signal processing | Heterodyne conversion |
Type of microphone | Electret-condenser |
Number of microphones | 1 |
Sensitivity range | 15–120kHz |
Live monitoring | Heterodyne |
Trigger function | yes |
Audio out | Speaker” |
Manual peak frequency selection | no |
Operation | |
Display | LED |
Interface | Push-button |
Casing | |
Size (WxLxD) | 130 x 130 x 78 mm |
Weight | 350g |
Protection class | IP66 |
Power | |
Power supply | 12 V DC to 18 V DC, min. 5W |
BATSCANNER STEREO
BATSCANNER STEREOSpecifications:
These are the specifications of the BATSCANNER STEREO
Field of application | Mobile bat detecton |
Audio | |
Acoustic signal processing | Stereo heterodyne conversion |
Type of microphone | Electret-condenser |
Number of microphones | 2 |
Sensitivity range | 15–120kHz |
Live monitoring | Heterodyne |
Trigger function | yes |
Audio out | 3.5mm plug / speaker |
Manual peak frequency selection | yes |
Operation | |
Display | 7-Segment LED |
Interface | Push-buttons |
Casing | |
Size (WxLxD) | 62 x 120 x 27 mm |
Weight | 145g |
Protection class | Not waterproof |
Power | |
Power supply | 3x 1,5 V batteries type AAA |
Operating time | 20-25h |
D100 Ultrasound Detector
D100 Ultrasound DetectorD100 Ultrasound Detector
Pettersson Elektronik, Sweden
Type: | Heterodyne |
Microphone: | Electret + ceramic |
Frequency range: | 10 – 120 kHz (min.) |
Bandwidth: | 8 kHz (+/- 4 kHz), -6 dB |
Battery: | 1 x IEC 6LF22 (9 V) |
Quiescent current: | 16 mA typ. |
Size: | 113 x 71 x 33 mm (113 x 71 x 63 mm including knobs) |
Weight: | 220 g including battery |
Outputs: | 2 x 3.5 mm jacks for headphones and recorder |
D1000X Ultrasound Detector
D1000X Ultrasound DetectorD1000X Ultrasound Detector
D1000X Ultrasound DetectorD1000X Ultrasound Detector
The D1000X is a professional ultrasound detector, based on the latest technology. The detector has heterodyne, frequency division and time expansion systems and also a built-in 16-bit recording system using a Compact Flash card as storage medium. It is equipped with our well-known, high-quality capacitance microphone which has been further improved to give lower noise, wider dynamic range and lower distortion.
The D1000X has a built-in “recorder”, relieving the user from the hassle of operating a separate recording device or laptop with connecting cables. It can be configured to work in a variety of operating modes, but thanks to the use of “Profiles”, switching between different modes is made instantly. Each profile contains all the selectable settings such as sampling rate, triggering mode, time expansion factor and LED intensity and can be prepared in advance and saved in the detector.
At any time, either the direct ultrasonic signal, the heterodyne signal or the frequency division signal can be recorded onto the CF-card. Spoken comments can be recorded by speaking into the microphone while recording in the direct mode, or in a special comment recording mode (at a lower sampling rate). The recording time is limited only by the available space on the CF-card. Upon completion of a recording in the direct mode, the signal will be automatically replayed in time expanded form, if this function is enabled. Time expansion factors from 1 (original speed) to 30 can be chosen. The recordings can be made by manually starting and stopping the recording or through level-activated (and optional frequency selective) triggering. In the latter case, the detector can be set up for unattended capture of calls. Pre- and post-triggering modes with a variety of different settings can be used.
The wav sound files on the CF-card are stamped with date and time and can be read directly on a PC, using a standard CF-card reader. The D1000X also has a serial GPS input, making it possible to save GPS position data in the files.
D200 Ultrasound Detector
D200 Ultrasound DetectorD200 Ultrasound Detector
Small and low weight heterodyne detector with backlit, large digit, accurate digital display, showing the tuned frequency. The frequency and volume controls are on the side of the case, making it easy to adjust.
Type: | Heterodyne |
Microphone | Electret |
Frequency range: | 10 – 120 kHz (min.) |
Display accuracy: | +/- 0.15 kHz |
Bandwidth: | 8 kHz (+/- 4 kHz), -6 dB |
Battery: | 1 x IEC 6LF22 (9V) |
Quiescent current: | 17 mA typ. including LCD backlight |
Size: | 119 x 60 x 25 mm including knobs |
Weight: | 150 g including battery |
Outputs: | 2 x 3.5 mm jacks for headphones and recorder |
D230 Ultrasound Detector
D230 Ultrasound DetectorD230 Ultrasound Detector
A combined heterodyne and frequency division detector with backlit, large digit, accurate digital display, showing the tuned frequency in the heterodyne mode. The frequency and volume controls are on the side of the case, making it easy to adjust. Using stereo headphones, the heterodyne signal is heard on the left channel and the frequency division signal on the right channel. When the built-in speaker is used, a switch is used to select the heterodyne or frequency division signal.
Weight | 160 g |
Dimensions | 119 × 60 × 25 mm |
Type | Heterodyne and frequency division |
Microphone | Electret |
Frequency range | 10-120 kHz (min.) |
Display accuracy | ± 0.15 kHz |
Bandwidth | 8 kHz (+/- 4 kHz), -6 dB |
Battery | 1 x IEC 6LF22 (9V) |
Quiescent current | 23 mA typ. including LCD backlight |
Outputs | 2 x 3.5 mm jacks for headphones and recorder |
D240x Ultrasound Detector
D240x Ultrasound DetectorD240x Ultrasound Detector
D240x Ultrasound DetectorD240x Ultrasound Detector
Very popular heterodyne and time expansion detector with backlit, large digit, accurate digital display, showing the tuned frequency in the heterodyne mode. The frequency and volume controls are on the side of the case, making it easy to adjust. Using stereo headphones, the heterodyne signal is heard on the left channel and the time expansion signal on the right channel. When the built-in speaker is used, a switch is used to select the heterodyne or time expansion signal.
A digital recorder can be connected to the D240X to record the time expanded calls for analysis on a PC. If the recorder has a “voice activated” recording mode, a fully automatic bat recording system is obtained, which can be left in the field for unattended recording of bat calls.
Weight | 170 g |
Dimensions | 119 × 60 × 25 mm |
Type | Heterodyne and time expansion (x10 or x20 – selectable via switch) |
Microphone | Advanced electret |
Frequency range | 10-120 kHz (min.) |
Display accuracy | ± 0.15 kHz |
Bandwidth | 8 kHz (+/- 4 kHz), -6 dB |
Battery | 1 x IEC 6LF22 (9V) |
Quiescent current | 30 mA typ. (replay) including LCD backlight |
Comment switch | Yes |
Memory size | 1M x 8 |
Sampling frequency | 307 kHz |
Resolution | 8 bits |
Storage time | 3.4, 1.7 or 0.1 sec. (selectable via switch) |
Trigger modes | Manual, level – broadband, level – narrowband |
Pretrigger | 50% of the selected storage time |
Outputs | 2 x 3.5 mm jacks for headphones and tape recorder |
Miscellaneous | Overload indicator, adjustable input gain, replay of signal in memory through heterodyne system |
D500X Ultrasound Detector/Recorder Mk I
D500X Ultrasound Detector/Recorder Mk ID500X Ultrasound Detector/Recorder Mk I
D500X Ultrasound Detector/Recorder Mk ID500X Ultrasound Detector/Recorder Mk I
The D500X is an ultrasound recording unit intended for long-term, unattended recording of bat calls. In contrast to time expansion bat detectors, the D500X records full-spectrum ultrasound in real time with virtually no gaps between recordings. The recorder is equipped with four slots for CF cards, which typically makes it possible to leave the unit in the field for more than a month. The triggering system allows the device to automatically start recording as a sound is detected.
Weight | 1200 g |
Dimensions | 165 × 170 × 53 mm |
Class | Direct, high-speed recording |
Microphone | Advanced electret, jack for external microphone |
Frequency range | 15 kHz – 190 kHz (500 kHz sampling rate, high-pass filter enabled) 5 kHz – 190 kHz (500 kHz sampling rate, high-pass filter disabled) |
Connections | External microphone, external trigger, external DC supply |
Timer | Four on/off periods per day |
Bandwidth | 8 kHz (+/- 4 kHz), -6 dB |
Batteries | 4 x AA size, Alkaline or NiMH recommended |
External DC supply | 5.5-8 V, typically ca. 200 mA (average, when recording), depends on CF card type and number of CF cards |
Recording | ADC Resolution: 16 bits Anti-aliasing filter: Yes, 8th order, 190 kHz cut-off frequency Sampling rates: 44.1, 300, 500 kHz (optimized for 500 kHz) Recording length: 0.3, 0.5, 1, 2, 3, 5, 10, 20 sec or manual recording Recording medium: CF card, 4 slots |